Home > Office Communicator > Ocs 2007 R2 Cwa Desktop Sharing Not Working

Ocs 2007 R2 Cwa Desktop Sharing Not Working

Contents

For those of you on the RTM version of MOC, you can directly upgrade to the R2 equivalent without first uninstalling the former. CNAME record download (example: as.cwa.company.local) Be sure that your CA accepts requests with san's in it. Additionally, you must manually install the Message Queuing (MSMQ) service on all R2 Front-End and Standard Edition servers, Monitoring Server and Archiving Server itself prior to deploying these 2 latter server Also note: a separate management console (mmc snap-in) is used to Administer CWA R2. http://cestudios.net/office-communicator/ocs-2007-r2-desktop-sharing-not-working.html

To get this to work try this: 1) Log into CWA 2) Click ‘Meet Now' 3) Click ‘Invite' > ‘Using Email' 4) Paste the guest URL that into a email 5) Reply Jenny says: May 7, 2009 at 6:12 am is there a keyboard shortcut to take control back when you are sharing control of your desktop? Subsequently, you assign the digital certificate that you prepared earlier to the Enterprise Edition server. If this is the first time you are sharing your desktop, you will be prompted to install the Microsoft Office Communicator Web Access plug-in. browse this site

Office Communicator Share Desktop Option Not Available

Charles July 26, 2013 Hi, We had OCS2007R2 in our env. This will probably be over kill but log on every component for the CWA server on it, and capture front end and web components where appropriate (if you have a consolidated I work with enterprises large and small to deploy unified communications solutions. You can use Table 1 as a guide to configure the appropriate internal DNS records to support such a scenario.

To allow users without Active Directory credentials to join the meeting, Communicator Web Access was also enhanced in Office Communications Server 2007 R2 to support anonymous sign-in upon receipt of a Once the Lync Prep has been completed, unless you restore from an AD Backup, you cannot prep for R2/R1 of OCS. An OCS 2007 R2 user must have the ‘Allow anonymous participant’ feature turned on to initiate a CWA conference (2+ participants). See DNS Requirements for Enterprise Pools and Standard Edition Servers for more information.

Help is appreciated. Office Communicator Desktop Sharing So in your case you cannot install a 2007 server as the schema was never prepped for 2007. It’s worth highlighting that it is still included in Office Pro Plus and Office Enterprise – many people aren’t aware of this. i thought about this By then creating your own counters, you can add counter-based metrics to anything that can be measured programmatically, such as services, applications, processes such as ETL, or deployments. … Read more

A good architecture overview of CWA R2 (on TechNet). With the named SQL database instance on the Back-End database ready, you can go ahead to run the Create Enterprise Pool task. RDP After the control information for the desktop sharing session has been exchanged and sharing has been initiated, the Remote Desktop Protocol (RDP) carries the stream of bitmaps (or JPEG images, I am a Microsoft MVP and Microsoft Certified Master for Lync.

Office Communicator Desktop Sharing

Check “Enable Program and Desktop Sharing” and “Allow control of shared programs and desktop” For anonymous desktop sharing use, select “Allow users to invite anonymous participants” within the OCS global properties other Is there a way to get this to work again? Office Communicator Share Desktop Option Not Available SignalR makes it even slicker; it can even update multiple pages at the same time. Office Communicator Share Desktop With Multiple Users View from desktop sharing host (above) View from someone joining a desktop session (above) Communicator Web Access desktop sharing (above) What is the desktop sharing architecture?

Friday, October 23, 2009 10:04 PM Microsoft is conducting an online survey to understand your opinion of the Technet Web site. this content As with IM or audio/video, if three or more participants are in the meeting, it becomes a conference, and the Focus Factory generates a Focus for the meeting and assigns it Now with Tutorials & Support Twitter LinkedIn grab this Home About Inside OCS Tips, Tricks, & Insight into Microsoft Office Communications Server Feeds: Posts Comments Posts Tagged ‘Communicator R2 Desktop Sharing' Furthermore, the Conferencing Server Factory and Focus have been enhanced to communicate with and manage the Application Sharing Conferencing Server.

By automating the process of gathering and storing appropriate counters, you can routinely check a range of devices quickly using visual tools such as PerfMon. Yes No Do you like the page design? Any anti virus that could be blocking this on the desktop side as well? weblink WPThemes.

Operations Administering Communicator Web Access Managing Communicator Web Access Servers Managing Communicator Web Access Servers Configuring Desktop Sharing Configuring Desktop Sharing Configuring Desktop Sharing Configuring Communicator Web Access Search Properties Configuring Eventually, Lync Web App will become a full featured web client, however, today it is only used for users to join online meetings from the web. Post to Cancel Home About Me Using OCS 2007 R2 CWA with Lync Server 2010 At this time, there are going to be a few scenarios where you may need to

Previously, the CDR service is an integral part of the Archiving and CDR Server (RTM).

You must pick a port that is not being used by an application currently. This is great for organizations who want to extend their infrastructure to the web via web conferencing, external telephony conferencing, or a bolt-on solution such as our SmartChat product, which enables CWA desktop sharing users need a browser add-on (CWAPlugin.exe) on their client machine. One important fact to know is that it is no longer possible to add RTM version of the CWA server role once you get pass the R2 Active Directory preparation steps.

The Application Sharing Conferencing Server also communicates with the Focus and Conferencing Server Factory over HTTPS/C3P using the same SSL certificate that is assigned to the other Office Communications Server services In order to support Macintosh and Linux users, Communicator Web Access displays the sharer’s desktop in the user’s browser window using AJAX Dynamic HTML (DHTML) over HTTPS. Nevertheless, you will want to perform tasks such as defining a new Exchange UM IP Gateway object and point it to the new R2 Mediation Server to optimize traffic routing, for http://cestudios.net/office-communicator/office-communicator-2007-desktop-sharing-not-working.html Randy Wintle December 19, 2010 Yup, all of my CWA installs since 2008 R2 support was available have worked fine.

The link for all of the pre requisites is here: http://support.microsoft.com/kb/982021/en-us Max DiOrio December 19, 2010 Has anyone installed CWA 2007 R2 on a Server 2008 R2 box and had Less You can use Communicator Web Access to share your desktop with other people. An OCS 2007 R2 user must be enabled for Web Conferencing and Program and Desktop sharing to use the desktop sharing feature in CWA. Subscribe in a reader Subscribe to Mike Stacy's Blog by Email Important Information:The views and opinions outlined within this blog are solely my own, and do not represent those of any

I can only get one-way communication through CWA. Posted at 22:06 in 2007, Licencing, Licensing, OCS, Office Communications Server, R2 | Permalink | Reblog (0) Comments You can follow this conversation by subscribing to the comment feed for this Create a free website or blog at WordPress.com. Johnny Diggs August 11, 2011 I noticed the call forwarding feature is no longer available when users are on the Lync pool.

With or without hardware load balancer, RTM and R2 server roles cannot co-exist in the same Front-End Pool, CWA server pools, an Edge array or Director array. This choice also means that much of the packet overhead imposed by SRTP/SRTCP provides little or no benefit to the RDP data that is carried over it. For those of you who intend to integrate R2 with the Unified Messaging feature in Exchange Server 2007 SP1 or an existing PBX, you should closely follow the TechNet Library documentation If the user’s computer does not already have this add-on, upon the user’s first attempt to share their desktop the browser will prompt him or her to download it from the

Microsoft TechNet portal for Deploying CWA R2. The Application Sharing Conferencing Server runs as a service on each Front End Server in a consolidated front-end topology and acts as a relay hub for desktop sharing sessions involving more After entering a description for your virtual web server, the most important part of this wizard is the Specify a Listening Port section. Click the arrow beside the Invite button, and then click Invite Using Email.

In contrast with the back-end R2 server roles, Windows client computers are not required to be 64-bit capable to run any of the R2 client applications. For administrators that are responsible for both the RTM and R2 infrastructure, it would be a good idea to use the same RTC* accounts in Active Directory. The Focus is instantiated as a SIP User Agent on one of the Front End Servers of the pool assigned to the person who initiated the meeting. Once you have published your topology, we will have one last step to verify our web server was imported correctly.